Kbiotech solutions for Risk-based stoichiometric process management, quantitative and qualitative multi-parameter process analysis, boosting process knowledge and safety. Our solutions also include TURBIDOSTAT operational mode and feedback control loop.

We offer the integration of online Biomass sensors such as Turbidity and Viable cell sensors compatible with the whole range of Kbiotech bioreactors, controllers and Bioflex sotware.

Kbiotech Bioflex Software provide an online data recording option and data processing and feedback controlled actions based on the biomass measurements to improve your bioprocess, cell growth and productivity.

On-line measurement of total cell density

The KBIO-OD-CELL sensor performs on-line measurement of total cell density in liquid solutions. The sensor is based on optical density, which measures the turbidity of the cell suspension. The measurement is made at NIR (near-infrared) wavelengths so it is insensitive to changes in media colour. All particles and molecules capable of absorbing or scattering light at 880 nm will be detected, including living and dead cells and cell debris.

Specifications

  • Sensor length: 120, 225, 325, 425 mm
  • Diameter: 25 or 12 mm
  • Applications: Autoclavable and SIP/CIP Bioreactors & Fermentors
  • Optical path length: 5 mm or 10 mm
  • Measuring principle: Absorbance
  • Wavelength: 880 nm (NIR)
  • Measuring range: 0 – 2500, equivalent to total cell density of 0.5 to 100 g/L dry weight
  • maximum temperature 135° C
  • Pressure range: 0 – 10 bar (25° C)
  • Data output: 4-20mA, Modbus

Features

  • Simple on-line measurement of cell growth
  • Reliable values during the growth phase
  • Early detection of process deviations

On-line measurement of viable cell density

Kbiotech LIVE-CELL sensor enables real-time, on-line measurement of viable cells in solution. The measurement is not influenced by changes in the media, microcarriers, dead cells, or debris. On-line measurement of viable cells makes it possible to detect events and respond in real time without sampling. The measurement principle is based on capacitance. In an alternating electrical field, viable cells behave like small capacitors. The charge from these small capacitors is measured by the sensor and reported as permittivity (capacitance per area).

Specifications

  • Sensor length: 120, 225, 325, 425 mm
  • Diameter: 25 or 12 mm
  • Applications: Autoclavable and SIP/CIP Bioreactors & Fermentors
  • Measurament principle: Capacitance
  • Measuring range: 0 – 700 pF/cm, equivalent to viable cell density of 5 to 200 g/L dry weight
  • Conductivity range standard: 2 – 50 mS/cm; LC: 0.5 – 10 mS/cm; HC: 5 – 100 mS/cm.
  • Maximum temperature: 135° C
  • Pressure range: 0 – 10 bar (25° C)
  • Data output: 4-20mA, Modbus

Features

  • Increase yield and lower production costs
  • Detect changes in cell physiology with frequency scanning
  • Precisely control harvesting for continuous culturing
  • Early detection of process deviations
  • Sensors optimised for multiple conductivity ranges.